RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations Despriction

(PDF) RULES FOR THE CLASSIFICATION AND

RULES FOR THE CLASSIFICATION AND CONSTRUCTION PART 1. SEAGOING SHIPS VOLUME V RULES FOR MATERIALS 2014 EDITION BIRO KLASIFIKASI INDONESIA3 - DNV GLWeb viewISO 14310:2001 drift mandrel cylinder, machined to specified dimensions, that is passed through a pipe to locate obstructions and/or to assess compliance with the appropriate specifications ISO 15463:2003 drift outside diameter tube's ID through which all elements of the assembled side-pocket mandrel can pass ISO 17078-1:2004 drift-off RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations7f154160665ca8f29db6fb0a592a4b11 Thermal Insulation RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsMarine Offshore Fire Divisions - bulkhead, deck floor systems 90 Penetration sealing. Penetration sealing SOLAS II-2 Regulation 9, Containment of fire Section 3 Penetrations in fire - resisting divisions and prevention of heat transmission has specific guidance on the treatment of penetrations through fire divisions. L1 + L2 =min. 900mm

All the information you need for classification purposes RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations

Lloyd's Register's Rules and Regulations set appropriate standards for the design, construction and lifetime maintenance of ships, offshore units and land-based installations - providing all the information you need for classification purposes.An overview of BLÜCHER's marine certificates and approvalsRS - 19.10096.262 BLÜCHER Pipe Penetration Type approval type 866, 868, 870, 871, 872 RS - 19.10097.262 BLÜCHER EuroPipe and HDPE pipes Type approval RS - 19.10098.262 BLÜCHER Marine Drains Type approvalApproval finder - DNV GLClear filters Export

At Sea

DNV GL class programme DNVGL-CP-0165 Type approval Cable and pipe penetrations Application Approved for use as penetration system for approved ship cables in class A steel or aluminium bulkheads and decks. This certificate is recognized by Transport Canada. Product(s) approved by this certificate is/are accepted for installation on RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsAt SeaDNV GL class programme DNVGL-CP-0165 Type approval Cable and pipe penetrations Application Approved for use as penetration system for approved ship cables in class A steel or aluminium bulkheads and decks. This certificate is recognized by Transport Canada. Product(s) approved by this certificate is/are accepted for installation on RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsCable penetration sealing system" Keyword Found DNVGL-CP-0165 Cable and pipe penetrations. Keyword-suggest-tool Cable and pipe penetrations DNV GL AS 1.4 Definitions Table 1 Definitions Term Definition penetration Same meaning as sealing system. Consist of a metal frame respectively case or conduit sleeve, the sealing material (sealing compounds, packing modules or plugs) the RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations

Certificates for Roxtec sealing solutions components RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations

We are ready to assist you in your safety work and solve your sealing problem, wherever you operate. Contact your nearest Roxtec office for guidance through design challenges or for questions regarding installation quality.. Contact our head office Call +46 455 Certificates for Roxtec sealing solutions components RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsWe are ready to assist you in your safety work and solve your sealing problem, wherever you operate. Contact your nearest Roxtec office for guidance through design challenges or for questions regarding installation quality.. Contact our head office Call +46 455 Certifications AquaPlusEstablished in 1864 as DNV, DNV-GL is an independent foundation with the objective of safeguarding life, property and the environment and is a leading international provider of services for managing risk. DNV-GL has certified our stainless steel compression ferrules SO 50001.

Chibro Arvedi Group

The range of diameters for Hermetic penetration tubes ranges from OD 14 mm to OD 273 mm. Penetration is designed and tested to support a hydrostatic water column head of 100 m and may therefore be used on ships and off-shore units of any size. Hermetic wall penetration is approved for all the afore-mentioned applications by the following:DNV GL - Approval Finder - DNVDNV GL approved products, manufacturers and service suppliers. DNV uses cookies to give you the best possible experience on our site. By browsing the site you agree to our use of cookies. You can click Close to remove this message.DNVGL-CP-0165 Cable and pipe penetrationsDNVGL-CP-0165, 2017 Edition, October 2017 - Cable and pipe penetrations This CP gives a description of the procedures and requirements related to documentation, design and type testing applicable for TA of cable and pipe penetrations with regard to fire safety, including watertightness and gastightness for class A penetrations.

DNVGL-CP-0165 Cable and pipe penetrations

Cable and pipe penetrations DNV GL AS 2.1.3 Water absorption Cured sealing compounds respectively injection mouldings shall not be hygroscopic, and shall not crack, swell or dissolve under the action of water. 2.2 Packing and plug systems Packing and plug systems shall have the following properties packing and plug systems shall be simple to fitEC-TYPE EXAMINATION MEDB0000128 CERTIFICATE This Certificate is issued by DNV GL AS under the authority of the Government of the Kingdom of Norway. This is to certify That the Penetrations through "A" class divisions pipe, duct, trunk, etc penetrations. with type designation(s) Roxtec sealing system with multidiameter technology RS-series (steel divisions) Issued to . Roxtec RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsFibre Optic Data Cables - Cable Solutions WorldwideFibre Optic and Data Cables (PDF datasheets) 28.6mm O/D - gel filled PBT tube with 12 fibres - 50/125 multimode - polyurethane sheath 6.0mm O/D - gel filled PBT tube with 2 x sm 9/125 + 2 x 62.5/125 fibres - colour codeds - galvanised steel wire braid - SHF2 outer sheath

File Size 306KBPage Count 24NOFIRNO System - Power and Cables

Mar 22, 2017Featured blog articles. How To Abandon Cables Using 3M Cold Shrink Cable Abandonment Kits CSCAK. Published 01 Aug 2017. uploaded by Chris Dodds - Thorne Derrick Sales Marketing Manager How To RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsFile Size 434KBPage Count 26BEELE Engineering bv/CSD International bvor NOFIRNO filler sleeves. The penetration is sealed on both sides with a layer of 20 mm FIWA or NOFIRNO sealant. Alt. 2 RIACNOF RISE Insert Sleeves wrapped around the cables and filling the remaining space in the conduit with ACTIFOAM filler sheets and strips. The penetration is sealed on both sides with a layer of 20 mm NOFIRNO sealant. Application/Limitation Approved for cable (incl. CLX and LAN cables) penetration Find a valid certificate - DNV GLThis list contains valid management system and product certificates issued by DNV on a global and local level. A search will give a customers certificate information, verifying that this company is certified by us, according to which standard, certification scope, etc.

Firesafe Energy AS

DNV GL rules for classification Ships DNV GL offshore standards DNV GL statutory interpretations DNVGL-SI-0364 SOLAS interpretations Application Approved for use as single pipe penetration system in A-0 in steel bulkheads. This certificate is recognized by Transport Canada. Product(s) approved by this certificate is/are accepted for RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsFiresafe Energy ASThat the Class A and B Penetration with type designation(s) A-60 Class Pipe pentrations through circular sleeve with GPG Marine Mortar sealing system Issued to Firesafe Energy AS Lørenskog, Norway is found to comply with DNV GL rules for classification Ships DNV GL offshore standards DNV GL statutory interpretations DNVGL-SI-0364 SOLAS RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsPipe insulation with Stenca PipeInsulation thickness of Stenca Pipe is 40 mm only. Stenca Pipe cloth is Sea Water UV-resistant. No CUI or water absorption by material. Installation is fast and easy - just wrap the sections around the pipe and seal them using the special sealant Stenca Seal. Stenca Pipe is unique, which makes it non-combustible according the EN ISO 1182:2010.

Quality Control System - Stenca Solutions - Insulation RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations

QUALITY SYSTEM . Stenca's Quality System has been approved by DNV GL Authority. Stenca's quality system is a supportive tool used to achieve our vision and overall objectives, which are the foundation of our business success in the insulation industry.Radox MFH-S Cables - Cable Solutions WorldwideThe extensive RADOX MFH-S cable portfolio (multi cores / twisted pairs screened / unscreened) meets the challenging demands for products on ships and on oil and gas platforms. Unlike rival products, the RADOX MFH-S cables can be used for transmitting both signals and energy.Radox MFH-S Cables - Cable Solutions WorldwideThe extensive RADOX MFH-S cable portfolio (multi cores / twisted pairs screened / unscreened) meets the challenging demands for products on ships and on oil and gas platforms. Unlike rival products, the RADOX MFH-S cables can be used for transmitting both signals and energy.

Roxtec International AB - Sealing solutions for cables and RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations

Approved for penetration in aluminium bulkheads or decks limited to a pressure of 4 bar watertightness and 2.67 bar gastightness. The pipe penetrations are not approved for use in watertight bulkheads on passenger ships and special purpose ships (SPS). For bolted versions with gasket and self tapping screws the pressure is limited to 3.33 barRules for Classification and Construction VI RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations - DNV GLInjection mouldings are products for sealing of spacing of pipe and cable penetrations. B.7 Mould and/or sealing length Mould and/or sealing length is the length of a cable and/or pipe penetration required to fulfil the require-ments of this Regulation in view of fire resistance, water and gas tightness. C Documents to be submittedSEACOR Thermoplastic Piping Systems WO Supply CatalogOverview. SeaCor ®, the first commercially available USCG approved thermoplastic piping system in the world, is a high performance CPVC polymer piping system that is ideal for fresh or salt water systems.. This plastic piping system meets IMO A753 (18) part 5, for low flame spread, along with part 2, for low smoke and toxicity. The SeaCor &system is ideal on shipboard systems due to its RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations

Sealing technology experts - Beele Engineering

Sealing Technology Experts. Quality, safety and reliability have formed the pillars of the Beele Engineering vision for almost half a century. As sealing technology experts we focus on optimal fire safety and water tightness. We can offer this guarantee because of Some results are removed in response to a notice of local law requirement. For more information, please see here.Some results are removed in response to a notice of local law requirement. For more information, please see here.Roxtec International ABDNV GL offshore standards Application Approved as penetration in -class H-0/H-60/H-120 decks/bulkheads for approved ship cables -class H60/H120 decks/bulkheads for steel pipes Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL. Issued at Høvik on 2018-06-29 This Certificate is valid RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations

TAF00000D8 TYPE APPROVAL CERTIFICATE

DNV GL offshore standards Application Approved as cable and pipe penetration in class H-60/H-120 decks and bulkheads. Approved as cable penetration in class H-0 bulkheads. This Certificate is valid until 2022-01-15. Issued at Høvik on 2017-01-31 DNV GL local station Malmö Approval Engineer Ivar Bull for DNV GL Petter Langnes Head of RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsTYPE APPROVAL CERTIFICATE - ViegaDNV GL rules for classification Ships Pt.4 Ch.6 Piping systems DNVGL-OS-D101 Marine and machinery systems and equipment, Edition January 2018 DNV GL class programme DNVGL-CP-0185 Type approval Mechanical joints Application Products approved by this certificate are accepted for installation on all vessels classed by DNV GL RISE NOFIRNO DNV GL Approved Pipe Sealine PenetrationsTYPE APPROVAL CERTIFICATEReference DNV GL Ship Rules Pt. 4, Ch. 6, Sec. 9 -5.2 Pipe couplings other than flanges, para. 5.2.1 and Table 8 Examples of mechanical joints Compression coupling Bite type. Approved scope of application according to Table 9 and 10 - Compression coupling Fire resistant type.

Type Approval from Lloyd's Register

Approval of Welding Consumables, Non-Metallic Materials and Coatings. Under this category, the manufacturers plant, method of production and the product can be approved subject to satisfactory inspection of the works and/or type testing. Typically, products need to comply with the LR Rules and international standards.rise nofirno dnv gl approved pipe sealing penetrations.Do you want results only for RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations?BEELE Engineering bv/CSD International bvThat the Class A and B Penetration with type designation(s) RISE, RIACNOF AND RISE/NOFIRNO - MULTI CABLE PENETRATION Issued to BEELE Engineering bv/CSD International bv AALTEN, Netherlands is found to comply with Det Norske Veritas' Interpretation of SOLAS 1974 Convention as Amended Det Norske Veritas' Rules for Classification of Shipsrise nofirno dnv gl approved pipe sealing penetrations.Do you want results only for RISE NOFIRNO DNV GL Approved Pipe Sealine Penetrations?RISE NOFIRNO DNV GL Approved Pipe Sealing PenetrationsSep 22, 2020For Multi-Mix Pipe, RISE/ULTRA strips/sleeves around the plastic pipes. The penetration is sealed on both ends with a layer of 20 mm NOFIRNO Sealant. Rise Nofirno Application/Limitation. Single pipe penetrations. Approved for A-0 penetrations for steel, copper and GRP service pipes of following maximum sizes Steel Ø408 mm; Copper.